Industries · Medical electronics
PCB manufacturer for medical electronics
Bare boards and assemblies for patient monitors, diagnostic instruments and laboratory equipment: fine-pitch multilayers with ENIG, built to IPC Class 3 when your device needs it, with a job record behind every board. Your device's regulatory file stays yours; we build exactly what it specifies.
- Build class
- Class 3 on request
- Finest BGA pitch
- 0.4 mm
- Smallest part
- 0201
- Components
- Lot and date-code traced
01Overview
What makes a PCB fit for a medical device?
Nothing in the laminate makes a board medical. What changes is the evidence around it: the device maker must show that every unit was built the same way, from known materials, to a defined acceptance standard, and must be able to find every affected unit if something goes wrong.
So a medical build is a fine-pitch build held to a stricter discipline: a frozen drawing and stack-up, IPC Class 3 acceptance where the risk analysis calls for it, components bought only through authorised channels with their lot and date codes recorded, and no silent substitution of laminate, finish or part on a repeat order.
The quality system that governs the device is yours, usually ISO 13485, and it controls us as a supplier. We work inside it: to your approved drawing, your part list and your inspection requirements, under our own ISO 9001:2015 certified quality management system.
Last updated
02Board selection
Which boards does a medical device contain?
| Board in the product | Construction | Base material | Finish | IPC class |
|---|---|---|---|---|
| 01Main processor board (monitor, analyser) | 6–8 layer multilayer | FR-4, Tg 170 °C | ENIG | Class 2 · 3 |
| 02ECG, SpO₂ and NIBP analogue front end | 4–6 layer multilayer | FR-4 | ENIG | Class 3 on request |
| 03Isolated medical power supply | Double-sided PTH | FR-4, Tg 170 °C | Lead-free HASL | Class 2 · 3 |
| 04Probe, sensor and wearable interconnect | Flexible circuit | Polyimide with coverlay | ENIG | Class 2 · 3 |
| 05Pump, heater and motor control (lab analysers) | Double-sided or 4 layer | FR-4 | ENIG or lead-free HASL | Class 2 |
| 06Display, keypad and touch-controller boards | 4 layer multilayer | FR-4 | ENIG | Class 2 |
IPC class belongs on each drawing, not on the product: a monitor's power board and its patient front end can justifiably sit in different classes. Class 3 adds inspection and lowers yield, so it belongs where your risk analysis puts it.
03Engineering
Where medical boards fail, and what we do about it
Medical failures are rarely dramatic. They are an intermittent joint, a leakage path that appears on humid days, or a part that quietly changed between two batches.
- Traceability
- Lifetime
- Humidity
- Signal integrity
- Voltage
P1Traceability
A field fault has to lead back to a lot
Job card · lot and date codeWhy boards fail
When a device is investigated or recalled, the maker must find every unit built from the same parts and process. A supplier with no record of which lot went into which boards turns a contained problem into a product-wide one.
How we handle it
Every job travels on a job card through all 13 production stages, and the job number ties the boards to that record. For assemblies, lot and date-code traceability on every part. Ask for a lot or date code in the legend and we print it where your drawing shows.
P2Lifetime
Class 2 margins where Class 3 is needed
IPC Class 3 on requestWhy boards fail
IPC Class 2 accepts features that are fine for most products: thinner hole-wall copper, a little annular-ring breakout, minor plating voids. In equipment that must work every time it is switched on, those margins are where intermittent faults begin.
How we handle it
Specify IPC Class 3 and we build and inspect to it: fabrication to IPC-6012 Class 3 and assembly to IPC-A-610 Class 3. Fine-pitch work is covered too, with BGAs down to 0.4 mm pitch inspected by X-ray.
P3Humidity
Residues that conduct only when it is humid
Requirement on the drawingWhy boards fail
Flux and process residues are invisible and harmless when dry. In a humid ward or a disinfected laboratory they absorb moisture and let ions migrate between closely spaced pads under bias: leakage on a high-impedance input first, a short later.
How we handle it
Put the cleanliness requirement on the assembly drawing: no-clean or washed flux, and any ionic limit your device file sets. We confirm at quote how the build will meet it, before anything is bought. Bare boards leave final inspection in protective packing.
P4Signal integrity
Microvolt signals beside a switching supply
4 / 4 mil · 1–12 layersWhy boards fail
An ECG electrode delivers about a millivolt; an EEG signal is tens of microvolts. A front end that shares a return path with a switch-mode supply or a display backlight shows it on the trace as mains hum and baseline wander.
How we handle it
Give the analogue front end its own ground plane on a four- or six-layer stack-up, guard high-impedance inputs and keep the supply's switching loop small. We build 4, 6, 8, 10 and 12 layers with stack-up support, to 4 / 4 mil fine-line where the parts need it.
P5Voltage
Patient isolation must hold on every layer
Barrier checked on every layerWhy boards fail
IEC 60601-1 asks for two means of patient protection between mains and the applied part: 8 mm of creepage at a 250 V working voltage. On a multilayer board a ground plane running under the isolation transformer quietly shortens the distance through insulation.
How we handle it
CAM checks the barrier against your drawing on every copper layer, inner layers included, before tooling. Slots under isolation parts are CNC-routed to ±0.15 mm, and the 100% electrical test proves the two sides share no net.
04Applications
Medical and laboratory equipment we build for

- A14–8 L · ENIG
Multiparameter patient monitors
Processor, analogue front-end, power and display boards
- A24–6 L
ECG, EEG and EMG recorders
Low-noise front ends with isolated interfaces
- A3Flex · 4 L
Pulse oximeters and wearables
Compact boards with flex links to the sensor
- A44–6 L
Diagnostic and point-of-care analysers
Optical, heater and pump-control boards around a processor
- A52–4 L
Laboratory equipment
Centrifuges, incubators and sample handlers
- A64 L · Class 3
Infusion and syringe pumps
Motor-control and alarm boards
- A72 L
Physiotherapy and hospital furniture
Stimulator, motor and keypad controllers
- Not listed?Send the drawing and a line about where the board will be used.Ask an engineer
05Specification
A starting specification for medical boards
| Construction | 4–8 layers for processor and front-end boards; double-sided for powerRange: 1 to 12 layers |
|---|---|
| Laminate | FR-4 Tg 170 °C for dense multilayers and lead-free assembly |
| Board thickness | 0.4–3.2 mm1.6 mm default; thinner for wearables |
| Min. track / space | 6 mil / 6 mil standard; 4 mil / 4 mil fine-line |
| Min. drill | 0.3 mm mechanical; 0.2 mm for fine-pitch designs |
| Surface finish | ENIG: flat, solderable pads for fine pitch and BGAAvailable: HASL · LF-HASL · ENIG · OSP |
| Build class | IPC Class 2 by default; Class 3 on requestFabrication per IPC-6012, inspection per IPC-A-600 |
| Flexible circuits | Single- and double-sided polyimide flex with polyimide coverlay12.5, 25 and 50 µm polyimide film |
| Assembly | 0201 (imperial) passives; 0.4 mm minimum BGA ball pitch; QFN, QFP and fine-pitch ICsIPC-A-610 Class 2 standard; Class 3 on request |
| Inspection | AOI at every stage; X-ray for BGA; functional test on request |
| Components | Lot and date-code traceability on every partAuthorised distributors and manufacturers only — no grey-market or broker stock |
| Electrical test | 100% electrical test — flying probe or bed-of-nails fixture — plus AOI |
How to order this spec
Priced online
Simple accessory and power boards (rigid single- and double-sided boards) can be priced live: 10 mm to 600 mm per side, 1 to 100,000 boards per line, dispatch in 3, 5, 7 or 10 working days.
Open the instant quoteReviewed by an engineer
Most medical work, meaning multilayer, Class 3, flex, assembly and sourcing, is quoted by an engineer after reviewing your drawing; we aim to reply within 24 hours on working days.
Request a quote06Traceability
From your files to dispatch, under one job number
01In
What you approve
- GBRFabrication data
- Gerber RS-274X (or X2) plus Excellon drill files; ODB++ accepted
- DWGFabrication drawing
- Stack-up, IPC class, laminate, finish, and any lot or date-code marking.
- BOMAssembly data
- Add a BOM (CSV / Excel, with manufacturer part numbers) and centroid / pick-and-place data
- QMSSupplier requirements
- What your quality system asks of us: build class, marking, cleanliness and the records to return.
02Process
The traveller it moves on
TRAVELLER
Specimen · our demo board
- Part / rev
- SBE-DEMO-04 · rev A
- Job no.
- J-2611-07
- Panel
- 2 × 2
- Lot · date code
- DC 2611
- Build class
- IPC Class 3
- Layers
- 4
- Finish
- ENIG
Route · 13 stages
- CAM & DFM review: CAM
- CNC drilling: CNC
- Hole metallisation: PTH
- Dry film & imaging: DRY
- Copper plating: PLT
- Etching: ETC
- Automated optical inspection: AOI
- Solder mask: LPI
- Surface finish: FIN
- Legend printing: LEG
- Routing & V-scoring: RTG
- Electrical test: E-T
- Final inspection: FQC
Sign-off
AOI
Passed
10.03.26
Every layer
E-T
Passed
12.03.26
Every net
FQC
Passed
13.03.26
IPC-A-600
Part lots, test log and inspection filed under J-2611-07
03Out
What leaves with the boards
- LEGMarked boards
- A lot or date code in the legend, wherever your drawing places it.
- E-TEvery net tested
- 100% electrical test — flying probe or bed-of-nails fixture — plus AOI
- LOTPart records
- Lot and date-code traceability on every part, bought from authorised distributors only.
- AOIAssembly inspection
- AOI at every stage; X-ray for BGA; functional test on request
07Standards context
Which standards govern medical electronics?
- ISO 13485
- Quality management for medical device manufacturers
- Your quality system. It controls us as a supplier through purchasing and supplier evaluation; we are not ISO 13485 certified ourselves.
- IEC 60601-1
- Basic safety and essential performance of medical electrical equipment
- Means of patient and operator protection (MOPP / MOOP), creepage, clearance and leakage-current limits.
- IEC 60601-1-2
- Electromagnetic compatibility of medical electrical equipment
- Immunity and emission tests; ground planes and stack-up are where the board helps.
- IPC-6012 / IPC-A-610
- Board performance and assembly acceptance, Class 2 or 3
- The build class your drawing calls up; Class 3 is available on request.
- Medical Devices Rules, 2017
- India's device regulation, administered by CDSCO
- Registration and licensing of the device sit with its manufacturer or importer.
Stays with you
Device classification, the ISO 13485 quality system, IEC 60601 testing and registration with CDSCO in India (or CE or FDA abroad) stay with the device maker. Your supplier controls, such as approved drawings, incoming inspection and audits, apply to us.
Comes from us
Boards built to your drawing and IPC class, with Class 3 on request, AOI, a 100% electrical test, final inspection to IPC-A-600, components from authorised distributors with lot and date-code records, and an ISO 9001:2015 certified quality management system.
09FAQ
Medical electronics: common questions
Not covered here? Ask an engineer — we aim to reply within 24 hours on working days.
What PCB is used in medical electronics?
Are you ISO 13485 certified?
Can you build medical PCBs to IPC Class 3?
How do you trace a medical board back to its build?
Do you change materials or components on repeat orders?
Who makes medical electronics PCBs in India?
Medical electronics
Send the drawing, with your quality requirements.
Upload Gerbers, the fabrication and assembly drawings, the approved BOM and any supplier requirements from your quality system. An engineer reviews them and replies with a quote that states the class, laminate and tests we will build to.