Industries · Railways
PCB manufacturer for railway electronics
Boards for signalling, traction control, passenger information and on-board electronics — equipment that rides a vibrating vehicle or stands in a trackside cabinet for decades. Multilayer and double-sided FR-4, high-Tg and heavy copper, built to IPC Class 3 on request.
- Laminate
- FR-4 Tg 170 °C
- Copper
- 1–3 oz
- Layers
- 1–12
- Build class
- IPC 2 · 3
01Overview
What does railway electronics ask of a PCB?
Railway electronics is defined by its service life. A coach, a locomotive or an interlocking is expected to run for decades, and the boards inside it are expected to last as long — or to be rebuilt, exactly, when they do not.
Rolling stock adds a harsh climate on board: continuous vibration and a shock at every rail joint, under-frame cabinets that bake in summer and start cold in winter, condensation as a train runs from a cold cutting into a humid station, and brake and pantograph dust. Trackside signalling equipment sees much the same from its location box.
The boards that survive it are unremarkable on paper — four- to eight-layer and double-sided FR-4 — and made with care: high-Tg laminate, heavy copper where current flows, generous annular rings, Class 3 plating and solid through-hole joints.
Last updated
02Board selection
Which boards does railway equipment use?
| Board in the product | Construction | Base material | Finish | IPC class |
|---|---|---|---|---|
| 01Axle-counter and track-circuit electronics | 4–6 layer multilayer | FR-4 Tg 170 °C | ENIG | Class 3 |
| 02Interlocking and data-logger I/O cards | Double-sided PTH or 4 layer | FR-4 | ENIG or lead-free HASL | Class 2 · 3 |
| 03Traction and auxiliary converter control | 6–8 layer multilayer | FR-4 Tg 170 °C, 2 oz copper | ENIG | Class 3 |
| 04On-board power supplies (110 V battery input) | Double-sided PTH | FR-4, heavy copper | Lead-free HASL | Class 2 · 3 |
| 05Passenger-information displays and LED boards | Double-sided PTH | FR-4 | Lead-free HASL | Class 2 |
| 06Train control, event-recorder and CCTV boards | 6–10 layer multilayer | FR-4, controlled impedance | ENIG | Class 2 · 3 |
Relays, transformers and heavy connectors still come through-hole on railway boards. Our line covers reflow, wave and selective / hand soldering, so a mixed board stays with one supplier.
03Engineering
Railway board problems, and how we solve them
A rail vehicle combines an industrial plant's electrical noise with a vehicle's vibration and an outdoor climate, for thirty years. These are the failures the board can prevent.
- Vibration
- Thermal
- Humidity
- Voltage
- Lifetime
P1Vibration
Every rail joint is a shock load
Thickness 0.4–3.2 mmWhy boards fail
Rolling stock vibrates continuously and takes a shock at every rail joint and set of points — hardest at the axle, less on the bogie, least in the body. Transformers, capacitors and relays load their joints; the board flexes; leads and barrels fatigue over the years.
How we handle it
Specify a thicker board for large cards (0.4–3.2 mm available) and Class 3 plating for the barrels. Mark heavy parts for staking on the assembly drawing and we confirm it at quotation; through-hole joints are wave- or selectively soldered and inspected to IPC-A-610.
P2Thermal
Cabinets bake in summer and start cold in winter
FR-4 Tg 170 °CWhy boards fail
EN 50155's hottest classes allow +85 °C air around the equipment, and power parts add their own rise on top; the coldest start at −40 °C. Laminate softens near its glass transition, and every swing strains the plated holes.
How we handle it
Use FR-4 Tg 170 °C for traction-control and power boards, so the laminate stays well below its glass transition in service, and Class 3 copper in the barrels for the cycling. Heavier copper, 3 oz (105 µm) and heavier on request, keeps current-carrying tracks cool.
P3Humidity
Condensation in the station, dust from the brakes
Tented vias · coating keep-outsWhy boards fail
A train running from a cold night into a humid station collects condensation on cold boards, and trackside location boxes breathe damp air every day. Add conductive dust from brakes and pantographs, and leakage paths grow between closely spaced conductors.
How we handle it
Full solder-mask coverage with tented vias leaves little bare copper to corrode. Most railway assemblies are conformally coated after assembly: put the material and its keep-outs on your drawing, and we choose a mask and finish it adheres to and agree the coating step at quotation.
P4Voltage
A battery bus with surges on it
Spacing checked in CAMWhy boards fail
On-board electronics run from the vehicle battery — 24 V to 110 V DC in EN 50155, with 110 V common on coaches — carrying surges and interruptions as loads switch. Inputs need creepage and clearance to the logic, and supply tracks carry real current.
How we handle it
CAM checks copper-to-copper spacing against the creepage on your drawing before tooling, and isolation slots are routed to ±0.15 mm as standard. Supply tracks get the copper weight their current needs, and the 100% net test proves the isolation.
P5Lifetime
Vehicles outlive the parts their boards were designed around
No MOQ · EOL reviewWhy boards fail
Rolling stock and signalling are maintained for decades. Spares are ordered years after the first build, in small numbers, and some of the original components are end-of-life by the time the depot asks for more.
How we handle it
There is no minimum order, so ten spare cards are a normal job. Your specification stays on file for the repeat, and our BOM review flags end-of-life parts and proposes drop-in alternatives for your approval. Authorised distributors and manufacturers only.
04Applications
Railway equipment we build boards for

- A14–6 L
Train detection
Axle counters, track circuits and detection evaluators
- A22–6 L
Electronic interlocking
Vital I/O, relay-interface and object-controller cards
- A36–8 L · 2 oz
Traction and auxiliary converters
Control, gate-drive and measurement boards
- A42–4 L
Passenger information
PIS and PA controllers, LED destination and coach displays
- A56–10 L
Train control and recording
Train-network nodes, event recorders and CCTV recorders
- A62–4 L
Coach systems
Lighting, HVAC, door and fire-detection controllers
- A72–6 L
Stations and trackside
Level-crossing, point-machine and station equipment controllers
- Not listed?Send the drawing and a line about where the board will be used.Ask an engineer
05Specification
A starting specification for railway boards
| Construction | 4–8 layer multilayer for control and signalling; double-sided PTH for power, I/O and displaysRange: 1 to 12 layers |
|---|---|
| Laminate | FR-4 Tg 170 °CFR-4 Tg 150 °C for low-power boards in mild locations |
| Board thickness | 1.6 mm; 2.0–2.4 mm for large or heavily loaded cardsRange: 0.4 mm to 3.2 mm standard; 0.2 mm for thin rigid designs |
| Copper weight | 1 oz (35 µm) and 2 oz (70 µm) standard; 3 oz (105 µm) and heavier on request |
| Min. track / space | 6 mil / 6 mil standard; 4 mil / 4 mil fine-lineWider spacing on supply and I/O nets, per your creepage |
| Annular ring | 0.15 mm minimum for drilled holes (design guideline) |
| Surface finish | ENIG for multilayer control boards; lead-free HASL for through-hole-heavy power and I/O boardsAvailable: HASL · LF-HASL · ENIG · OSP |
| Mask and legend | Green mask; white legend with part number, revision and date code |
| Electrical test | 100% electrical test — flying probe or bed-of-nails fixture — plus AOI |
| Assembly | SMT, through-hole (THT) and mixed technology; reflow, wave and selective / hand solderingIPC-A-610 Class 2 standard; Class 3 on request |
| Components | Authorised distributors and manufacturers only — no grey-market or broker stockLot and date-code traceability on every part |
How to order this spec
Priced online
Double-sided display, I/O and power boards — rigid single- and double-sided boards — can be priced online for prototypes and spares: 1 to 100,000 boards per line, dispatch in 3, 5, 7 or 10 working days.
Open the instant quoteReviewed by an engineer
Multilayer control boards, Class 3 builds, heavy copper, assembly and coating requirements are quoted by an engineer, who aims to reply within 24 hours on working days.
Request a quote06Standards context
Which standards apply to railway electronics?
- EN 50155
- Railway applications — electronic equipment on rolling stock
- Operating-temperature classes OT1–OT6, supply-voltage range and interruptions, and the type tests the finished unit must pass.
- IEC 61373
- Rolling-stock equipment — shock and vibration tests
- Category 1 body-mounted, 2 bogie-mounted, 3 axle-mounted: the mounting position sets the test severity.
- EN 50121-3-2
- EMC of rolling-stock apparatus
- Emission and immunity of the equipment; ground planes and filtering on the board are where much of it is won.
- EN 45545-2
- Fire protection on railway vehicles — requirements for materials
- Fire behaviour of the equipment's materials, assessed by its maker; ask for laminate datasheets with the quotation.
- RDSO specifications
- Indian Railways' technical specifications and vendor approval
- Approval belongs to the equipment maker, for its product; the boards are built to that maker's drawing.
Stays with you
EN 50155 compliance, IEC 61373 and EN 50121 testing, the fire-safety assessment, RDSO or operator approval and the equipment's safety case stay with the maker that supplies the railway. We are not an RDSO-approved vendor and do not claim to be.
Comes from us
Boards built to IPC Class 2 by default and Class 3 on request, to your drawing and stack-up, on high-Tg FR-4 where specified, with AOI, a 100% electrical test, final inspection to IPC-A-600 and an ISO 9001:2015 certified quality management system.
07EN 50155 context
Temperature classes, and where the laminate sits
- OT1−25…+55 °C
- OT2−40…+55 °C
- OT3−25…+70 °C
- OT4−40…+70 °C
- OT5−25…+85 °C
- OT6−40…+85 °C
- Hot spotOT6 + rise
Classes per EN 50155:2017, air temperature around the equipment. Context for your design; the standard applies to your equipment, not to the bare board.
- N1
The cabinet is rarely the limit
Even OT6's +85 °C leaves 65 K to the Tg of standard FR-4. Power parts eat into that margin locally, which is why traction-control and converter boards go to Tg 170 °C.
- N2
Cycling is the slow failure
A daily swing from a cold start to full load, repeated for decades, fatigues plated barrels. Class 3 hole-wall copper and a generous annular ring buy the extra life.
- N3
Cold starts bring condensation
OT2, OT4 and OT6 start at −40 °C. Warming in humid air condenses water on the board: tented vias, full mask coverage and a conformal coat keep it off the copper.
09FAQ
Railways: common questions
Not covered here? Ask an engineer — we aim to reply within 24 hours on working days.
What PCB is used in railway electronics?
Are you RDSO approved or EN 50155 certified?
Who makes railway PCBs in India?
Which laminate suits EN 50155 temperature classes?
Can you supply small batches of spare boards for older equipment?
Railways
Send the drawing — for the first build and every spare after it.
Upload Gerbers, drill files, the drawing and your class, laminate and coating requirements. An engineer reviews them and replies with a quote; double-sided spares can be priced online straight away.