Industries · Renewable energy
Solar inverter PCB manufacturer for renewable energy
Power boards for string and hybrid inverters, MPPT charge controllers, battery management systems and energy-storage converters: circuits that carry tens of amps at hundreds of volts DC, outdoors, for as long as the panels feeding them. Heavy copper, high-Tg FR-4 and routed isolation slots, made in Gandhinagar since 2000.
FIG. 01Top copper of a single-phase inverter power stage. The dashes trace the load current.
- ADC+ and DC− pours in 2 oz copper, stitched with via rows
- BDC-link capacitors across the DC+ / DC− gap
- CFull bridge: TO-263 switches on copper heat-spreading tabs
- DRouted isolation slot, gate-driver isolators across it
- ELow-voltage control section with the DSP
- Copper
- 1–3 oz and heavier
- Laminate
- FR-4 Tg 170 °C
- Board thickness
- 0.4–3.2 mm
- Electrical test
- 100% of boards
01Overview
What does a solar inverter ask of its PCB?
A solar inverter is a small power station in a sealed box. Its boards switch tens of amps on a DC link of several hundred volts, sit in an enclosure that bakes on a roof or a ground-mount frame, and are expected to keep converting for twenty years or more.
That shapes the board in three ways: copper thick enough to carry the current without cooking the laminate around it, spacing and routed slots wide enough for the DC voltage, and a laminate that survives a daily heat cycle for decades. The control, communication and BMS boards beside the power stage are ordinary FR-4 multilayers; the hard engineering sits on the power board.
Axpert is on our customer list. The first prototype of a new MPPT stage and the repeat batch of a charge controller already in the market come off the same line in Gandhinagar, built to the same drawing every time.
Last updated
02Board selection
Which boards go into an inverter or a battery system?
| Board in the product | Construction | Base material | Finish | IPC class |
|---|---|---|---|---|
| 01Inverter power stage (DC link, H-bridge, output filter) | Double-sided PTH, heavy copper | FR-4, Tg 170 °C | Lead-free HASL | Class 2 · 3 |
| 02MPPT boost and DC-DC stages | Double-sided or 4 layer | FR-4, 2 oz copper | Lead-free HASL | Class 2 |
| 03Control and DSP board | 4–6 layer multilayer | FR-4 | ENIG | Class 2 |
| 04Isolated gate-driver board | 4 layer multilayer | FR-4, Tg 170 °C | ENIG | Class 2 · 3 |
| 05BMS cell-monitor and balancing board | Double-sided or 4 layer | FR-4 | ENIG | Class 2 · 3 |
| 06PWM and small MPPT charge controllers | Double-sided PTH | FR-4, 2 oz copper | Lead-free HASL | Class 2 |
Surface-mount MOSFETs and diodes that need a heat path are backed by wide copper pours and rows of thermal vias to the enclosure. Copper weights: 1 oz (35 µm) and 2 oz (70 µm) standard; 3 oz (105 µm) and heavier on request.
03Copper and current
How wide does a power track need to be?
Outer layer · 10 °C rise · IPC-2221
- 1 oz 35 µm
- 2 oz 70 µm
- 3 oz 105 µm
- 5A0.10 mm²2.8 mm · 1 oz1.4 mm · 2 oz0.92 mm · 3 oz
- 10A0.25 mm²7.2 mm · 1 oz3.6 mm · 2 oz2.4 mm · 3 oz
- 20A0.66 mm²18.7 mm · 1 oz9.4 mm · 2 oz6.2 mm · 3 oz
- 30A1.1 mm²32.7 mm · 1 oz16.4 mm · 2 oz10.9 mm · 3 oz
N1The formula behind the bars
I = k · ΔT0.44 · A0.725, where A is the cross-section in mil² and k is 0.048 for outer layers. Width × thickness = A, so twice the copper needs half the width for the same current.
N2Inner layers need more copper
An inner track cannot shed heat to the air, so k halves and the same current needs about 2.6× the cross-section: 24.3 mm of 2 oz for 20 A instead of 9.4 mm on the surface.
N3A starting point, not a sign-off
IPC-2152 refines the estimate with board thickness, nearby planes and mounting, and often allows narrower tracks. Use it, or a thermal simulation, for the final width.
N4What we build
1 oz (35 µm) and 2 oz (70 µm) standard; 3 oz (105 µm) and heavier on request. Heavier copper needs wider gaps to etch cleanly, so ask for the minimum track and space at your copper weight before layout.
04Engineering
Power-board failures, and how we build against them
Inverters and battery systems fail slowly: a track that runs hot for years, a surface that tracks under DC, a plated hole that cracks after its seven-thousandth sunrise.
- Current
- Voltage
- Thermal cycling
- Humidity
- Signal integrity
P1Current
Tens of amps through a copper track
Copper 1–3 oz · 35–105 µmWhy boards fail
Temperature rise follows current, copper cross-section and how easily heat leaves the board. A track sized on a calculator for 2 oz but built in 1 oz runs hot, browns the laminate around it and drifts the current-sense reading next to it.
How we handle it
Size the copper for the current. We build 1 oz (35 µm) and 2 oz (70 µm) standard; 3 oz (105 µm) and heavier on request. Doubling the copper roughly halves the width a track needs (drawn to scale below), and wide pours stitched to the other side with rows of plated vias share the load.
P2Voltage
Hundreds of volts DC across the surface
Routed slots · CTI on the drawingWhy boards fail
PV strings reach 1,000 V DC, and 1,500 V in utility plants; a residential DC link sits around 400 V. DC never crosses zero, so once dust and moisture start a leakage path along the surface, it keeps growing into a carbonised track.
How we handle it
CAM checks copper-to-copper and copper-to-edge spacing against your drawing before tooling. Isolation slots are CNC-routed at their finished width to ±0.15 mm (±0.1 mm on request). If your creepage calculation assumes a laminate CTI above standard FR-4, state it on the drawing and we confirm the laminate at quote.
P3Thermal cycling
A heat cycle every day for twenty years
FR-4 Tg 170 °C · Class 3 on requestWhy boards fail
Each sunrise heats the power stage and each sunset cools it: more than 7,000 cycles over a twenty-year design life. Laminate expands through its thickness far more than the copper barrel of a plated hole, so thin plating cracks at the corner of the hole.
How we handle it
Build power boards on Tg 170 °C FR-4, which expands less in the z-axis below its Tg, and specify IPC Class 3 where life matters: thicker hole-wall copper and tighter acceptance on every plated hole.
P4Humidity
Condensation inside an outdoor enclosure
LPI mask · LF-HASL or ENIGWhy boards fail
Charge controllers and inverters live on rooftops, in battery rooms and in pump houses, where night-time condensation and fine dust settle on the board. Moisture on bare copper between high-voltage nets starts leakage first and corrosion later.
How we handle it
Keep solder mask over every high-voltage track and open it only where something is soldered; we hold the mask layer as drawn. Lead-free HASL or ENIG seals the exposed pads. If the assembly is conformally coated, leave the keep-outs for connectors and test points in the layout.
P5Signal integrity
Millivolt cell readings beside a switching stage
4 L · continuous ground planeWhy boards fail
A BMS measures each cell to a few millivolts while a converter switches tens of amps nearby. Switching noise and balancing currents couple into the sense lines, and the state-of-charge estimate wanders.
How we handle it
Put the cell-monitor front end on four layers with an unbroken ground plane, route sense lines as tight pairs away from the power pours, and keep heavy copper on the power board. We build 4, 6, 8, 10 and 12 layers with stack-up support.
05Applications
Renewable-energy products we make boards for

- A12–6 L · heavy Cu
String and hybrid solar inverters
Power stage, control, gate-drive and communication boards
- A22 L · 2 oz
MPPT and PWM charge controllers
Boost or buck stage and its controller, often on one board
- A32–4 L · ENIG
Battery management systems
Cell-monitor, balancing and pack-controller boards
- A44–8 L
Energy-storage converters
Bidirectional DC-DC and power-conversion-system control
- A52–4 L · heavy Cu
Solar pump controllers
Motor-drive boards for agricultural PV water pumps
- A64 L · Tg 170
Micro-inverters and optimisers
Dense power boards that sit behind each panel
- A72–4 L
Monitoring and data loggers
Wi-Fi, GSM and RS-485 monitoring and metering boards
06Specification
A starting specification for power boards
| Construction | Double-sided PTH for power stages; 4–6 layers for control, gate-drive and BMSRange: 1 to 12 layers |
|---|---|
| Laminate | FR-4 Tg 170 °C for power boards; standard FR-4 for controlState any CTI requirement on the drawing |
| Board thickness | 1.6 mm default; up to 3.2 mm for large, terminal-loaded power boardsRange: 0.4 mm to 3.2 mm standard; 0.2 mm for thin rigid designs |
| Copper weight | 1 oz (35 µm) and 2 oz (70 µm) standard; 3 oz (105 µm) and heavier on request2 oz is the usual starting point for a power stage |
| Min. track / space | 6 mil / 6 mil standard; 4 mil / 4 mil fine-lineHeavier copper needs wider gaps: ask before layout |
| Min. drill | 0.3 mm mechanical; 0.2 mm for fine-pitch designs |
| Isolation slots | CNC-routed at finished width, ±0.15 mm as standard; ±0.1 mm on request |
| Surface finish | Lead-free HASL for power boards; ENIG for control and BMSAvailable: HASL · LF-HASL · ENIG · OSP |
| Solder mask | Green LPI over all high-voltage copper; openings only where soldered |
| Electrical test | 100% electrical test — flying probe or bed-of-nails fixture — plus AOI |
| Assembly | SMT, through-hole (THT) and mixed technologyReflow, wave and selective / hand soldering |
| Components | Authorised distributors and manufacturers only — no grey-market or broker stock |
How to order this spec
Priced online
Simple charge-controller and auxiliary-supply boards (rigid single- and double-sided boards) are priced live: 10 mm to 600 mm per side, 1 to 100,000 boards per line, dispatch in 3, 5, 7 or 10 working days.
Open the instant quoteReviewed by an engineer
Heavy-copper power stages, multilayer control and BMS boards, assembly and sourcing are quoted by an engineer, who aims to reply within 24 hours on working days.
Request a quote07Standards context
Which standards apply to inverters and storage?
- IEC 62109-1 / -2
- Safety of power converters for photovoltaic systems
- Insulation, creepage and clearance for PV inverters and charge controllers, for DC inputs up to 1,500 V.
- IS 16221
- Indian adoption of IEC 62109 (Parts 1 and 2)
- The standard behind BIS registration of solar inverters sold in India.
- IEC 62477-1
- Safety of power electronic converter systems
- General insulation coordination for converters, including storage power-conversion systems.
- IEC 62619
- Safety of lithium cells and batteries for industrial use
- Energy-storage batteries; the BMS is part of the safety case it asks for.
- IEC 60664-1
- Insulation coordination for low-voltage equipment
- Creepage tables by working voltage, pollution degree and the laminate's CTI material group.
- UL 94 V-0
- Flammability of plastic materials
- The flammability class FR-4 laminates are rated to by their makers. Board-level UL recognition is a separate listing we do not hold.
Stays with you
Product safety approval (IEC 62109, IS 16221 and BIS registration where it applies), grid-connection compliance and battery-system certification stay with the inverter or storage maker. The board is one tested component of that product.
Comes from us
Boards built to IPC Class 2 by default and Class 3 on request, to your drawing, copper weight and spacing, with AOI, a 100% electrical test, final inspection to IPC-A-600 and an ISO 9001:2015 certified quality management system.
09FAQ
Renewable energy: common questions
Not covered here? Ask an engineer — we aim to reply within 24 hours on working days.
What PCB is used in a solar inverter?
What copper weight do inverter and BMS power boards need?
Who makes solar inverter PCBs in India?
How do you handle creepage on high-voltage DC boards?
Can you build and assemble BMS boards for lithium battery packs?
Renewable energy
Send the power board. We will build the copper you drew.
Upload Gerbers, drill files and your fabrication drawing with copper weight, thickness and any CTI or class requirement. An engineer reviews them and replies with a quote.